Step 01:
Remove the AN4 bolt, used to locate the glued washers, from each of the
stabilator hinge brackets, refer to Figure 2. |
|
Step 02: Rotate the
WD-1223 Counterbalance Arm 90°, keep the counterbalance arm within both
WD-122 Counterbalance Brackets. Insert the lead weights into the hole in
the aft bulkhead of the Tailcone Assembly. Turn the counterbalance arm
back to the original position as indicated by "top" from the previous
step. Re-install the counterbalance hardware called out in Figure 1. |
|
Step 03:
Install the Stabilator Assembly to the Tailcone Assembly using hardware
called out in Figure 2. Refer to
Page 10-05-02 for previous
information about glued washers. |
|
Step 04:
Check the Stabilator Assembly movement to make sure it swings freely.
Stabilator travel in both directions should only be limited by the
HS-1210 Hinge stops contacting the F-1211C Hinge Bracket shown in Figure
2, Detail A-A. |
|