Page 11.05
Emp Attach |
|
Step 01:
Remove any curve from the F-1278B Doublers
if required by hammering them until they lay flat. Separate the
doublers by removing the material shown hatched in Figure1. Deburr both
parts.
08/23/10 |
 |
Step 02: Separate the
F-1287J Doublers from the F-1287A Servo Tray by removing the material
called out in Figure 2. Deburr all the parts.
08/23/10 |
 |
Step 03: Mark then
separate The F-1287D-L & R Clevis Plates by removing the material called
out in Figure 3.
08/23/10 |
 |
Step 04: Fabricate the
F-1287G and F-1287H Spacers from the At6-058 X 5/16" aluminum tube per
the dimensions given in Figure 4.
Builder Note: 1000/32 = 31.25
1000/8 = 125 28/32"= 7/8" or .875" 1.15/32"= 1.467 |
|
Page 11.05