NOTE: The spars in Figure 1 are shown
unbent and oriented as if the Flanges will be bent down. All
Countersinking done on the spars and spar caps will be done on the outer
surfaces. Step 01: Machine countersink the HS-1202 Fwd Spar for 1/8" rivets in the holes on both of the flanges as callout in Figure 1. 08/06/10 |
||||||||||||
Step 02: Machine
countersink the HS-1203 Aft Spar for 1/8" rivets in the holes on both
flanges as called out in Figure 1. 08/06/10 |
||||||||||||
Step 03: Machine
countersink the HS-1202 Fwd Spar for 3/32" rivets in the nutplate attach
rivet holes on the web as called out in Figure 1. 08/06/10 |
||||||||||||
Step 04:
Machine countersink both of the HS-1211 Spar Caps for 3/32" rivets in
the holes called out in Figure 1. 08/06/10 |
||||||||||||
Step 05:
Machine countersink the HS-1213 Hinge Bracket at the nutplate attach
rivet holes for 3/33" rivets per call-outs in Figure 2.
08/06/10 |
||||||||||||
Step 06:
Final-Drill #12 the HS-1213 Hinge Bracket through all of the 3/16" holes
as called out in Figure 2.
08/06/10 |
||||||||||||
Step 07: Trim The HS-1213 Hinge Brackets to make the HS-1213A In-bd
and HS-121B Out_bd Hinge Brackets by removing the material shown
hatched in Figure 2. Deburr all edges and drilled holes. 08/06/10 |
||||||||||||
Step 08: Machine countersink the #40 holes in the HS-1209 Spar
Cap Spacers for 3/32" rivets per call-out in Figure 3. 08/06/10 |
||||||||||||
Step 09: Separate the
HS-1209 Spar Cap Spacers by remove the material shown hatched in Figure
3. 08/06/10 |
||||||||||||
Step 10: Separate the HS-1224 Doublers by removing the material
shown hatched in Figure 4. Deburr the edges of the separated parts. 08/06/10 |
||||||||||||